  • Error Code: 16032. Company is Currently not connected with Tally.NET. Sync. Initiation complete.

    12-01-2021 23:11:08
    1. Synchronising using Tally.NET Servers Cause The corresponding company or companies at the synchronization client are not connected to Tally.NET. Solution Ens...
  • Error code 6243. Internal error

    12-01-2021 23:11:40
    Cause The site is not approved by the account administrator. Solution Contact the account administrator to confirm the activation of the site. Update the license. Conne...
  • Handshake failed

    12-01-2021 23:14:30
    Cause The server is unable to get rule information while synchronizing data. Moreover, the handshake process may fail if a firewall is installed on your system and Tally URLs are not allowed by the firewall. ...
  • Unable to reach Tally.NET Server / Failed to post to http://t009.tallyenterprise.com:80

    12-01-2021 23:15:07
    Cause Tally.NET server access may be blocked by proxy, firewall, or routers. Solution Enter the following URL in the browser: http://tallynet.tallyenterprise.com. You will receive a messa...
  • Post Error 11001 unknown status

    12-01-2021 23:15:32
    Cause The system fails to find the host while connecting to Tally.NET, or while synchronizing the data. ...
  • Failed to post. Error code 10054. Unknown Status. Unable to establish session.

    12-01-2021 23:16:05
    Cause While synchronising data, the Maximum Transmission Units are less than the recommended number. ...
  • Company is not connected. Error Code: 16032

    12-01-2021 23:17:03
    Cause This error occurs during synchronisation due to one of the following reasons: The Company is no...
  • Error 404

    12-01-2021 23:17:58
    Cause This error appears in the Event Log while synchronising data, due to mismatch in voucher numbering method at the server and the client. At one end the&...
  • Ledger name already exists

    12-01-2021 23:18:26
    Cause This error may occur due to either of the following reasons: The same ledger on both the client and server systems have different alias names. Different ledgers on both the client and server syst...
  • Out of Memory

    12-01-2021 23:19:01
    Cause There are circular references in the Bills of Material (BOM). For example, while configuring BOM in I...
  • Running as ODBC Server in the synchronisation client where as it should display Running as Client without ODBC

    12-01-2021 23:19:29
    Cause This message is displayed in the About page when ODBC server is enabled. Solution On the client: Gateway of Tall...